Current Probe and Power Supply
USER MANUAL
GW INSTEK PART NO. 82CP-425P0M01
ISO-9001 CERTIFIED MANUFACTURER
Seitenansicht 0
1 2 3 4 5 6 ... 39 40

Inhaltsverzeichnis

Seite 1 - USER MANUAL

Current Probe and Power Supply USER MANUAL GW INSTEK PART NO. 82CP-425P0M01 ISO-9001 CERTIFIED MANUFACTURER

Seite 2

GCP Series User Manual 10 WARNING • Do not allow the device to get wet, and do not take measurements with wet hands. This may cause an electri

Seite 3 - Table of Contents

PRECAUTIONS 11 • The sensor head is a precision assembly including a molded component, a ferrite core, and a Hall effect element. It may be damag

Seite 4 - TABLE OF CONTENTS

GCP Series User Manual 12 NOTE • Correct measurement may be impossible in the presence of strong magnetic fields, such as near transformers and h

Seite 5 - SAFETY INSTRUCTIONS

OVERVIEW 13 OVERVIEW Current Proble Overview This device can be directly connected to a BNC input connector of a waveform measuring instrument s

Seite 6

GCP Series User Manual 14 Names of Parts(Current Probe) External view

Seite 7 - PRECAUTIONS

OVERVIEW 15 Parts of the Sensor X Opening lever Operating lever for opening the sensor head. Always use this lever to open the sensor head. Y Sens

Seite 8 - (core and

GCP Series User Manual 16 DANGER To avoid electric shock, do not touch the portion beyond the protective barrier during use. NOTE • The output of

Seite 9

OVERVIEW 17 Names of Parts(Power supply) Front view PowerindicatorPowersupplyreceptaclesPowerindicatorPowersupplyreceptacles GCP

Seite 10

GCP Series User Manual 18 Front view GCP-206P Rear View GCP-206P

Seite 11

OVERVIEW 19 Power Supply Receptacle

Seite 12

November 2010 edition This manual contains proprietary information, which is protected by copyright. All rights are reserved. No part of this manua

Seite 13 - OVERVIEW

GCP Series User Manual 20 MEASURE PROCEDURE Preparations for Measurement (Current Probe) Procedure 1. Have the GCP-206P or GCP-425P POWER SUPPLY

Seite 14 - External view

OVERVIEW 21 4. Turn the GCP-206P or GCP-425P power switch

Seite 15 - Parts of the Sensor

GCP Series User Manual 22 Demagnetizing and Zero Adjustment Procedure 1. With the waveform measurement instrument input at ground, adjust the tr

Seite 16

OVERVIEW 23 • Do not demagnetize while the GCP-530 or GCP-1030 is clamping a conductor to be measured. Demagnetizing causes current to flow into

Seite 17 - Names of Parts(Power supply)

GCP Series User Manual 24 Measurement Procedure (Current Probe) Procedure 1. Check that the system is safe, and that the preparations described

Seite 18

OVERVIEW 25 5. It is now possible to monitor the current waveform. The output rate of the GCP-530 or GCP is 0.1 V/A. The current sensitivity can

Seite 19 - Receptacle

GCP Series User Manual 26 CAUTION • The maximum continuous input range is based on heat that is internally generated during measurement. Never in

Seite 20 - MEASURE PROCEDURE

OVERVIEW 27 • Do not place any unclamped conductor with an electric current of a frequency of 10 kHz or more near the sensor head. Current flowin

Seite 21

GCP Series User Manual 28 • Depending on the measured current frequency, however some sound may be produced by resonance, it has no effect on me

Seite 22

OVERVIEW 29 • At high frequencies, common mode noise may affect measurements taken on the high voltage side of circuits. If this occurs, reduce t

Seite 23

TABLE OF CONTENTS 3 Table of Contents SAFETY INSTRUCTIONS ... 5Safety Symbols ...

Seite 24

GCP Series User Manual 30 Preparations (Power supply) Procedure 1. Turn the power switch off and connect the power cord. To ensure safety, conne

Seite 25

OVERVIEW 31 Measurement Procedure (Power supply) NOTE • Make sure the sum of the current consumption of the connected current probe(s) does not

Seite 26

GCP Series User Manual 32 APPENDIX The power supply fuse for the GCP-425P, and the power supply voltage selector, are housed in the power input so

Seite 27

APPENDIX 33 3. Remove the fuse on the fuse holder and replace with a new one of the same rating and specification. 4. Insert the fuse holder

Seite 28

GCP Series User Manual 34 Change the power supply voltage setting Procedure 1. Repeat steps 1-2 in the “Fuse replacement” section on page 32. 2

Seite 29

APPENDIX 35 Current Probe Specifications Accuracy is guaranteed at 23°C~+5°C (72°F±9°F) after the power has been on for 30 minutes. Model-specific

Seite 30 - Preparations (Power supply)

GCP Series User Manual 36 Common specifications (for GCP-530 and GCP-1030) GCP-530 GCP-1030 Operating temperature and humidity range 0 to 4

Seite 31

APPENDIX 37 External dimensions Sensor: Approx. 175(W)×18(H)×40(D)mm Approx. 6.89"(W)×0.71"(H)×1.58"(D)(excluding protrusions) Ter

Seite 32 - APPENDIX

GCP Series User Manual 38 Fig.4 Input impedance (For GCP-530) Frequency [Hz]Input inpedance[Ω ]1m10m100m110100 1k 10k

Seite 33

APPENDIX 39 Power Supply Specifications Model-specific specifications Cable Lengths Sensor cable Approx. 1.5 m (59.0"), Power supply cable

Seite 34

TABLE OF CONTENTS 4

Seite 35 - Amplitude [dB, 0dB=1V]

GCP Series User Manual 40 Rated supply frequency 50/60 Hz Common specifications (for GCP-206P and GCP-425P) Compatible sensors GCP-530, GCP-103

Seite 36 - GCP Series User Manual

SAFETY INSTRUCTIONS 5 SAFETY INSTRUCTIONS Safety Symbols This manual contains information and warnings essential for safe operation of the device an

Seite 37 - APPENDIX

GCP Series User Manual 6 The following symbols in this manual indicate the relative importance of cautions and warnings. DANGER Indicates that inc

Seite 38

PRECAUTIONS 7 PRECAUTIONS Follow these precautions to ensure safe operation and to obtain the full benefits of the various functions. Preliminary C

Seite 39 - Power Supply Specifications

GCP Series User Manual 8 Un-insulated (core and shield case) • Be careful to avoid damaging the insulation surface while taking measurements.

Seite 40

PRECAUTIONS 9 2. If basic insulation requirements cannot be met between the terminal to which this device is connected and other terminals of the