Gw-instek GBS-1000 Series Programming Manual Bedienungsanleitung Seite 66

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 88
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 65
GBS-1000 Programming Manual
66
:MEASure:VAVerage
Query
Returns the average voltage.
Same as: Measure key F1~F5 F3 (Vavg)
< Long >
< Short >
:measure:vaverage?
:meas:vavg?
<NR3>
Select the measurement channel before this
command: :measure:source <NR1>. See pagexx.
:measure:source 1
:measure:vaverage?
Select channel 1, then
measure average
Voltage.
:MEASure:VHI
Query
Returns the global high voltage.
Same as: Measure key F1~F5 F3 (Vhi)
< Long >
< Short >
:measure:vhi?
:meas:vhi?
<NR3>
Select the measurement channel before this
command: :measure:source <NR1>. See pagexx.
:measure:source 1
:measure:vhi?
Select channel 1, then
measure global high
Voltage.
Seitenansicht 65
1 2 ... 61 62 63 64 65 66 67 68 69 70 71 ... 87 88

Kommentare zu diesen Handbüchern

Keine Kommentare