:MEASure:VMIN
Query
Description
Returns the minimum amplitude.
Same as: Measure key F1~F5 F3 (Vmin)
Syntax
< Long >
< Short >
:measure:vmin?
:meas:vmin?
Returns
<NR3>
Note
Before using this command, select the
measurement channel. See the example below.
Example
:measure:source 1
:measure:vmin?
Selects Channel 1, and
then measures the
minimum amplitude.
:MEASure:VPP
Query
Description
Returns the peak-to-peak amplitude (difference
between maximum and minimum amplitude)
Same as: Measure key F1~F5 F3 (Vpp)
Syntax
< Long >
< Short >
:measure:vpp?
:meas:vpp?
Returns
<NR3>
Note
Before using this command, select the
measurement channel. See the example below.
Example
:measure:source 1
:measure:vpp?
Selects Channel 1, and
then measures the
peak-to-peak
amplitude.
:MEASure:VRMS
Query
Description
Returns the root-mean-square voltage.
Same as: Measure key F1~F5 F3 (Vrms)