Gw-instek GDS-2000 series Programming manual Bedienungsanleitung Seite 21

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 93
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 20
GDS-2000 Series Programming Manual
21
For the actual value of the parameter type <Boolean>, you have to enter 0 instead
of “OFF” or enter 1 instead of “ON”.
The following example includes both the header and a value for the parameter type:
:TRIGger:NREJ 0
Parameter values that appeared in this manual are often separated by a vertical
line. This vertical line means the same thing as the word "or," For example, values
for the parameter <Boolean> are
0|1
This is the same thing as saying "0 (off) or 1 (on)" Any single value is a valid
parameter.
Message Terminator and Message Separator
In accordance with IEEE 488.2 standard, this oscilloscope accepts any of the
following message terminators:
z LF
^
END Line feed code (hexadecimal 0A) with END message
z LF Line feed code
z <dab>
^
END Last data byte with END message
These terminators are compatible with most application programs.
A semicolon separates one command from another when the commands appear on
the same line.
Seitenansicht 20
1 2 ... 16 17 18 19 20 21 22 23 24 25 26 ... 92 93

Kommentare zu diesen Handbüchern

Keine Kommentare