Gw-instek GPI-700A Series Programming Manual Bedienungsanleitung Seite 24

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 31
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 23
GPI/GPT SERIES PROGRAMMABLE EST
PROGRAMMER MANUAL
45
Return:
<NR2>
Examples:
:DCWStanding:TTIMe 5.0 set the DCW test time to 5 sec.
:DCWStanding:TTIMe? return 005.0 if the DCW test time setting is 5 sec.
:IRESistance:VOLTage
Function:
Set or query the IR test voltage.
Syntax:
:IRESistancce:VOLTage <NR1>
:IRESistancce:VOLTage?
<NR1> Please refer to the specification
Return:
<NR1>
Examples:
:IRESistancce:VOLTage 100 set the IR test voltage to 100V.
:IRESistancce:VOLTage? return 0100 if the IR test voltage setting is 100V.
:IRESistance:RMINimum
Function:
Set or query the IR test minimum resistance.
Syntax:
GPI/GPT SERIES PROGRAMMABLE EST
PROGRAMMER MANUAL
46
:IRESistance:RMINimum <NR1>
:IRESistance:RMINimum?
<NR1> Please refer to the specification
Return:
<NR1>
Examples:
:IResistance:RMINimum 100 set the IR test minimum resistance to 100MΩ.
:IResistance:RMINimum? return 0100 the IR test minimum resistance setting is
100MΩ.
:IRESistance:RMAXimum
Function:
Set or query the IR test maximum resistance.
Syntax:
:IRESistance:RMAXimum <NR1>
:IRESistance:RMAXimum?
<NR1> Please refer to the specification
Return:
<NR1>
Examples:
:IRESistance:RMAXimum 100 set the IR test maximum resistance to 100MΩ.
:IRESistance:RMAXimum? return 0100 the IR test maximum resistance setting
is 100MΩ.
Seitenansicht 23
1 2 ... 19 20 21 22 23 24 25 26 27 28 29 30 31

Kommentare zu diesen Handbüchern

Keine Kommentare