2.7GHz Spectrum Analyzer Operation Manual
5
FOR UNITED KINGDOM ONLY
NOTE: This lead / appliance must only be wired by competent persons
WARNING: THIS APPLIANCE MUST BE EARTHED
IMPORTANT: The wires in this lead are coloured in accordance with the following code:
Green/ Yellow: Earth
Blue: Neutral
Brown: Live (Phase)
As the colours of the wires in main leads may not correspond with the colours marking identified in
your plug/appliance, proceed as follows:
The wire which is coloured Green & Yellow must be connected to the Earth terminal marked with
the letter E or by the earth symbol or coloured Green or Green & Yellow.
The wire which is coloured Blue must be connected to the terminal which is marked with the letter
N or coloured Blue or Black.
The wire which is coloured Brown must be connected to the terminal marked with the letter L or P
or coloured Brown or Red.
If in doubt, consult the instructions provided with the equipment or contact the supplier.
This cable/appliance should be protected by a suitably rated and approved HBC mains fuse: refer to
the rating information on the equipment and/or user instructions for details. As a guide, cable of
0.75mm
2
should be protected by a 3A or 5A fuse. Larger conductors would normally require 13A
types, depending on the connection method used.
Any moulded mains connector that requires removal /replacement must be destroyed by removal of
any fuse & fuse carrier and disposed of immediately, as a plug with bared wires is hazardous if a
engaged in live socket. Any re-wiring must be carried out in accordance with the information
detailed on this lable.
Use and Wear
CAUTION
Do not exceed +30 dBm into the RF INPUT or +30 dBm reverse power into the TG OUTPUT.
Do not place any heavy object on the instrument.
Avoid severe impacts or rough handling that could damage the GSP-827.
Use electrostatic discharge precautions while handling and making connections to the GSP-827.
Do not place wires into the connectors of the GSP-827, only mating connectors and adapters.
Do not block or obstruct cooling fan vent opening on side panels or on the rear panel of unit.
This equipment is not for measurements performed for CAT II, III, and IV.