Gw-instek GDS-200 Series Programming Manual Bedienungsanleitung Seite 65

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 139
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 64
COMMAND DETAILS
65
Example
:MEASure:SOURce1 CH1
:MEASure:RMS?
1.31E-3
Selects Channel 1, and then measures the RMS
voltage/current.
:MEASure:CRMS
Description
Returns the root-mean-square voltage/current of
one full period.
Syntax
:MEASure:CRMS?
Related
Commands
:MEASure:SOURce<X>
Return parameter
<NR3>
Returns the CRMS value.
Chan Off
Indicates the source channel is not
activated.
Note
Before using this command, select the
measurement channel. See the example below.
Example
:MEASure:SOURce1 CH1
:MEASure:RMS?
1.31E-3
Selects Channel 1, and then measures the CRMS
voltage/current.
:MEASure:AREa
Description
Returns the voltage/current area over one or more
full periods.
Syntax
:MEASure:AREa?
Related
Commands
:MEASure:SOURce<X>
Return parameter
<NR3>
Returns the area value.
Query
Query
Seitenansicht 64
1 2 ... 60 61 62 63 64 65 66 67 68 69 70 ... 138 139

Kommentare zu diesen Handbüchern

Keine Kommentare