COMMAND DETAILS
73
:REF<x>:TIMebase:POSition
Set
Query
Description
Sets or returns the selected reference waveform
time base position.
Syntax
:REF<x>:TIMebase:POSition { <NRf> | ?}
Parameter
<x>
Reference
waveform
<NRf>
1,2,3,4
REF1~REF4
Horizontal co-
ordinates
Return parameter
Returns the reference waveform position as
<NR3>.
Example
:REF1:TIMebase:POSition -5.000E-5
Selects reference 1, and then sets the horizontal
position to -50us.
:REF<x>:TIMebase:SCALe
Set
Query
Description
Sets or returns the selected reference waveform
time base scale.
Syntax
:REF<x>:TIMebase:SCALe { <NRf> | ?}
Parameter
<x>
Reference
waveform
<NRf>
1,2,3,4
REF1~REF4
Horizontal scale
Return parameter
Returns the reference waveform scale as <NR3>.
Example
:REF1:TIMebase:SCALe 5.00E-4
Selects reference 1, and then sets the horizontal
scale to 500us/div.