REMOTE CONTROL
81
[:SOURce]:CURRent:SLEW:FALLing
Sets or queries the falling current slew rate. This is
only applicable for CC slew rate priority mode.
[:SOURce]:CURRent:SLEW:FALLing
{<NR2>(A)|MINimum|MAXimum}
[:SOURce]:CURRent:SLEW:FALLing?
Per-Step is Rated Current divided by 100msec
Minimum falling current slew rate
Maximum falling current slew rate
SOUR:CURR:SLEW:FALL MAX
Sets the falling current slew rate to the maximum.
Returns the status of the output mode (CC, CV,
Off) of the power supply.
The interface will return “CV’ if the supply is in
Constant Voltage Mode, “CC” if the supply is in
Constant Current Mode or “OFF” if the supply
output is off.
Returns the output state as a string, “CC”,
“CV”, “OFF”
:SOUR:MODE?
>CC
The power supply is currently in CC mode.
[:SOURce]:RESistance[:LEVel][:IMMediate]
[:AMPLitude]
Sets or queries the internal resistance in ohms.
Kommentare zu diesen Handbüchern