:SYSTem:CONFigure:PROTection:RECovery
Sets or queries how the OHP, FAN, AC-FAIL, and
SD alarms are cleared.
:SYSTem:CONFigure:PROTection:RECovery
{SAFE|AUTO}
:SYSTem:CONFigure:PROTection:RECovery?
The output is not turned on automatically
when the cause of the alarm is fixed.
The output is turned on automatically
when the cause of the alarm is fixed.
Sets or queries the unit operation mode. This
setting is only applied after the unit has been reset.
:SYSTem:CONFigure:MSLave { <NR1> }
:SYSTem:CONFigure:MSLave?
Master/with 1 unit in Parallel (total:2 units)
Master/with 2 units in Parallel (total: 3 units)
Master/with 3 units in Parallel (total: 4 units)
:SYSTem:CONFigure:OUTPut:EXTernal
[:MODE]
Sets the external logic as active high or active low.
This setting is only applied after the unit has been
reset.
:SYSTem:CONFigure:OUTPut:EXTernal[:MODE]
{<NR1>|LOW|HIGH}
:SYSTem:CONFigure:OUTPut:EXTernal[:MODE]?