Description
Sets or queries the EOF character for the UART
packet setting.
Syntax
:BUS1:UART:EOFPAcket <NR1>
Parameter/Return
parameter
<NR1>
0: NULL
1: LF (line feed)
2: CR (carriage return)
3: SP (space character)
4: FF
Example
:BUS1:UART:EOFPAcket 2
Sets the OEF character to CR.
:BUS1:UART:TX:SOURce
Description
Sets or queries which channel is used for the
UART Tx source.
Syntax
:BUS1:UART:TX:SOURce { OFF| D0 | D1 | D2 | D3 | D4
| D5 | D6 | D7 | D8 | D9 | D10 | D11 | D12 | D13 | D14 |
D15 | ? }
Parameter/Return
parameter
OFF
Off, no Tx source
D0 to D15
Digital channels D0 to D15
Example
:BUS1:UART:TX:SOURce D1
Sets channel D1 as the Tx source.
:BUS1:UART:RX:SOURce
Description
Sets or queries which channel is used for the
UART Rx source.
Syntax
:BUS1:UART:RX:SOURce { OFF| D0 | D1 | D2 | D3 | D4
| D5 | D6 | D7 | D8 | D9 | D10 | D11 | D12 | D13 | D14 |
D15 | ? }
Parameter/Return
parameter
OFF
Off, no Rx source
D0 to D15
Digital channels D0 to D15
Set
Query
Set
Query