GDS-2000A Programming Manual
64
:CURSor:MODe
Description
Sets cursor mode to horizontal (H) or horizontal
and vertical (HV).
Note: When the cursor source is set to logic or bus,
then only the horizontal cursor is available.
Syntax
:CURSor:MODe {OFF | H | HV | ? }
Parameter
OFF
Turns the cursors off.
H
Turns the horizontal cursors on.
HV
Turns horizontal and vertical cursors on.
Return parameter
Returns the state of the cursors (H, HV, OFF).
Example
:CURSor:MODe OFF
Turns the cursors off.
:CURSor:SOURce
Description
Sets or queries the cursor source.
Syntax
:CURSor:SOURce {CH1 | CH2 |CH3 | CH4 | REF1 |
REF2 | REF3 | REF4 | MATH | LOGic | BUS1 | ?}
Parameter
CH1~CH4
Channel 1 to 4
REF1~4
Reference waveform 1 to 4
MATH
Math source
LOGic
Logic source
BUS1
Bus source
Return parameter
Returns the cursor source.
Example
:CURSor:SOURce CH1
Turns the cursor source as channel 1.
Set
Query
Set
Query