COMMAND DETAILS
93
:MEASure:LOW
Description
Returns the low voltage/current.
Syntax
:MEASure:LOW{?}
Related
Commands
:MEASure:SOURce<X>
Return parameter
<NR3>
Returns the global low value.
Chan Off
Indicates the source channel is not
activated.
Note
Before using this command, select the
measurement channel. See the example below.
Example
:MEASure:SOURce1 CH1
:MEASure:LOW?
1.00E-0
Selects Channel 1, and then measures the low
current/voltage.
:MEASure:MAX
Description
Returns the maximum amplitude.
Syntax
:MEASure:MAX{?}
Related
Commands
:MEASure:SOURce<X>
Return parameter
<NR3>
Returns the maximum amplitude.
Chan Off
Indicates the source channel is not
activated.
Note
Before using this command, select the
measurement channel. See the example below.
Query
Query