Gw-instek GDS-2000A series Programming Manual Bedienungsanleitung Seite 201

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 272
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 200
COMMAND DETAILS
201
:SEARCH:TRIGger:BUS:B1:I2C:CONDition
Description
Sets or queries the I
2
C search trigger conditions.
Syntax
:SEARCH:TRIGger:BUS:B1:I2C:CONDition
{STARt | STOP | REPEATstart | ACKMISS | ADDRess |
DATA | ADDRANDDATA | ? }
Parameter
STARt
Set Start as the I
2
C search trigger
condition.
STOP
Set Stop as the I
2
C search trigger
condition.
REPEATstart
Set Repeat of Start as the I
2
C
search trigger condition.
ACKMISS
Set Missing Acknowledgement
as the I
2
C search trigger
condition.
ADDRess
Set Address as the I
2
C search
trigger condition.
DATA
Set Data as the I
2
C search trigger
condition.
ADDRANDDATA
Set Address and Data as the I
2
C
search trigger condition.
Return parameter
Returns the I
2
C bus search trigger condition.
Example
:SEARCH:TRIGger:BUS:B1:I2C:CONDition ADDRess
Set Address as the I
2
C search trigger condition.
:SEARCH:TRIGger:BUS:B1:I2C:ADDRess:M
ODe
Description
Sets or queries the I
2
C addressing mode (7 or 10
bits) for the search trigger.
Syntax
:SEARCH:TRIGger:BUS:B1:I2C:ADDRess:MODe
{ADDR7 | ADDR10 | ? }
Set
Query
Set
Query
Seitenansicht 200
1 2 ... 196 197 198 199 200 201 202 203 204 205 206 ... 271 272

Kommentare zu diesen Handbüchern

Keine Kommentare