Programmable DC Electronic Load PEL-2000 Series PROGRAMMING MANUAL GW INSTEK PART NO. 82EL-20040IA1 ISO-9001 CERTIFIED MANUFACTURER
PEL-2000 Programming Manual 10 Functionality check Run this query command via the terminal. *idn? This should return the Manufacturer, Model numbe
PEL-2000 Programming Manual 100 Example :PROG:ONT 10S Set the on-time for the current program number to 10 seconds. Query Syntax :PROGram:ONTime?
COMMAND DETAILS 101 :PROGram:RUN All Channel Command Description Runs the current program number when set to on, and when set to off will allow a
PEL-2000 Programming Manual 102 0.0~119.9 Returns the P/F-Time for the program sequence. Query Example :PROG:PFTime? 5 The P/F-Tme is 5 seconds.
COMMAND DETAILS 103 Resistance Subsystem :RESistance[:STATic]:L1/L2 ... 103 :RESistance[:STATic]:RISE/FALL
PEL-2000 Programming Manual 104 Example :RES:L1 10 Sets CR static mode A Value to 10 ohms, depending on the specific range Query Syntax :RESistanc
COMMAND DETAILS 105 Return Parameter <NR2> [MAX|MIN] Slew rate 1 Unit =1 amp/uS Returns the slew rate. MAX/MIN Returns the allowable maxim
PEL-2000 Programming Manual 106 BVALue 20 Sets B Value to 20 ohms. (Low Range only) AVALue MIN Sets A Value to the minimum level for the specifi
COMMAND DETAILS 107 Example :RES:STAT:LOW:RISE 0.1 Sets the rising slew rate to 0.1A/uS. Query Syntax :RESistance:STATic:LOW:RISE/FALL? [MIN|MAX]
PEL-2000 Programming Manual 108 Query Syntax :RESistance:STATic:HIGH:AVALue/BVALue? [MAX|MIN] Return Parameter <NR2> [MAX|MIN] Resistance
COMMAND DETAILS 109 Query Example :RES:STAT:HIGH:RISE? MIN 0.8000 For high range CR mode, the minimum value for the rising slew rate is 0.8 A/uS f
INTERFACE OVERVIEW 11 GPIB Interface Configuration Panel operation 1. Press the Shift Key then the Help key to access the Utility menu. UTILITYH
PEL-2000 Programming Manual 110 :RESistance:DYNamic:LOW:RISE/FALL Channel Specific Command Description Sets the low range rising/falling slew rat
COMMAND DETAILS 111 Parameter <NRf+>[S] Time T1/T2 T1/T2 0.1S Sets the T1/T2 time to 0.1 seconds. T1/T2 1 Sets T1/T2 to 1 second. T1/T2 M
PEL-2000 Programming Manual 112 L1/L2 MIN Sets L1 or L2 to the minimum level for the specific channel. L1/L2 MAX Sets L1 or L2 to the maximum le
COMMAND DETAILS 113 Query Syntax :RESistance:DYNamic:HIGH:FALL? [MIN|MAX] Return Parameter <NR2> [MAX|MIN] Slew rate 1 Unit=1 amp/uS Return
PEL-2000 Programming Manual 114 Query Example :RES:DYN:HIGH:T1? 2.5 :RES:DYN:LOW:T1? MIN 0.000025 Returns the T1 time of 2.5 seconds. Returns the
COMMAND DETAILS 115 RUN Subsystem :RUN ... 115 :RUN All Channel Comm
PEL-2000 Programming Manual 116 SHOW Subsystem :SHOW[:DISPlay] dual channel ... 116 :SHOW[:DISPlay] single channe
COMMAND DETAILS 117 :SHOW[:DISPlay] single channel Channel Specific Command (Single channel module) Description Sets the display mode of the loa
PEL-2000 Programming Manual 118 SPECIFICATION Subsystem :SPECification:UNIT ... 118 :SPECificat
COMMAND DETAILS 119 :SPECification[:PASS]? Channel Specific Command Description Displays if the Go/NoGo (specification) limit has passed/failed f
PEL-2000 Programming Manual 12 GPIB constraints Maximum 15 devices altogether, 20m cable length, 2m between each device Unique address assig
PEL-2000 Programming Manual 120 :SPECification:VOLTage:H/L/C Channel Specific Command Description Sets the high(H), low(L) and center(C) Go/NoGo
COMMAND DETAILS 121 Return Parameter <NR2> Go/NoGo voltage 1 unit = 1 amp Returns the limit current Query Example :SPEC:CURR:H? 5.120 The
PEL-2000 Programming Manual 122 STATUS Subsystem :STATus:CHANnel:CONDition? ... 122 :STATus:CHANnel:ENABle ...
COMMAND DETAILS 123 :STATus:CHANnel:ENABle Channel Specific Command Description Sets which events are enabled in the Channel Status Enable regis
PEL-2000 Programming Manual 124 Return Parameter <NR1> Event <NR1> Event 1 OC 16 OT 2 OV 32 G/N 4 OP 64 UVP 8 RV 128~65535 Not Use
COMMAND DETAILS 125 Query Syntax :STATus:CHANnel:NTRansition/PTRansition? <NR1> Return Parameter <NR1> Event <NR1> Event 1 OC 1
PEL-2000 Programming Manual 126 Query Example :STAT:CSUM:ENAB? 4 Only the events from channel 3 can set the CSUM bit in the Status Byte Register.
COMMAND DETAILS 127 Query Example :STAT:QUES:COND? 2 OV (overvoltage) error. :STATus:QUEStionable:ENABle Channel Specific Command Description Se
PEL-2000 Programming Manual 128 Query Syntax :STATus:QUEStionable[:EVENt]? <NR1> Return Parameter <NR1> Event <NR1> Event 1 OC
COMMAND DETAILS 129 Example :STAT:QUES:NTR 5 OC (Bit 1) and OP (Bit 3) are set as negative transitions. :STAT:CHAN:PTR 2 OV (Bit 2) is s
COMMAND OVERVIEW 13 COMMAND OVERVIEW The Command overview chapter lists all the PEL-2000 commands and command queries .The command syntax section
PEL-2000 Programming Manual 130 Voltage Subsystem :VOLTage:L1/L2 ... 130 :VOLTage:RECall
COMMAND DETAILS 131 MAX/MIN Returns the allowable maximum and minimum. Query Example :VOLT:L1? 5 :VOLT:L1? MAX 81.6000 A Value is set to 5 volts.
PEL-2000 Programming Manual 132 MAX Sets the voltage to the maximum value for the channel Example :VOLT:AVAL 10V Sets A Value to 10 volts for the
COMMAND DETAILS 133 MAX Sets the current limit to the maximum value for the channel Example :VOLT:CURR 1A Sets the current limit to 1 Amp for the
PEL-2000 Programming Manual 134 Return Parameter <NR1> Response Time 0 Slow 1 Fast Query Example :VOLT:MODE? 0 The specific channel is se
COMMAND DETAILS 135 Power Subsystem :POWer:L1/L2 ... 135 :POWer:CURRent ...
PEL-2000 Programming Manual 136 1 unit = 1 watt Returns the power of the A Value (L1) or B Value (L2). MAX/MIN Returns the allowable maximum and
COMMAND DETAILS 137 Query Example :POW:CURR? 7.0 Returns the current limit for the specific channel. :POWer:RECall Channel Specific Command Desc
PEL-2000 Programming Manual 138 AVALue MAX Sets A Value to the maximum Level for the specific channel. Example :POWer:LOW:AVAL 1 Sets A Value to
COMMAND DETAILS 139 Query Syntax :POW:LOW:CURRent? [MAX|MIN] Return Parameter <NR2> [MAX|MIN] Current 1 unit = 1 amp Returns the current
PEL-2000 Programming Manual 14 Command forms Commands and queries have two different forms, long and short. The command syntax is written with the
PEL-2000 Programming Manual 140 Query Example :POWer:HIGH:BVAL? AX 2 Returns the maximum power allowed for the channel/range. :POWer:HIGH:CURRent
COMMAND DETAILS 141 SYSTEM Subsystem :SYSTem:ERRor? ... 141 :SYSTem:VERSion?...
PEL-2000 Programming Manual 142 :SYSTem:SETup System Command Description Sets or returns the system setup for the current settings using block da
COMMAND DETAILS 143 Memory Subsystem :MEMory:SAVE:PREset ... 143 :MEMory:SAVE:PROGram ...
PEL-2000 Programming Manual 144 Example :MEM:SAVE:PROG 100 Saves the channel to Memory M100. :MEMory:SAVE:ALLPreset All Channels Description S
COMMAND DETAILS 145 Example :MEM:REC:PRE 0 Recalls the preset settings from (P0). :MEMory:RECall:PROGram Channel Specific Command Descrip
PEL-2000 Programming Manual 146 Example :MEM:REC:SET 1 Recalls the setup data from S1 (applicable to all channels). Example :MEM:REC:100
COMMAND DETAILS 147 Return Parameter <block data> Returns the program data as block data. Query Example :MEM:FILE:PROG? #<digits><
PEL-2000 Programming Manual 148 Return Parameter <block data> Returns the sequence data as block data. Query Example :MEM:FILE:SEQuence? #&
COMMAND DETAILS 149 SEQuence Subsystem :SEQuence:EDIT:POINt ... 149 :SEQuence:END ...
COMMAND OVERVIEW 15 Parameter Type Description Example <Boolean> Boolean logic 0, 1 <NR1> integers 0, 1, 2, 3 <NR2> decimal
PEL-2000 Programming Manual 150 Query Example :SEQ:EDIT:POIN? 3 The current point is 3. :SEQuence:END Channel Specific Command Description Sets
COMMAND DETAILS 151 1 unit = 1 ohm Returns the resistance value. MAX/MIN Returns the allowable maximum and minimum. Query Example :SEQ:POIN:RES?
PEL-2000 Programming Manual 152 1.2 1.2A/us 1.2 A/us 1.2A/us MAX/MIN Maximum or minimum value. Example :SEQ:POIN:RISE .3 A Sets the rising sle
COMMAND DETAILS 153 Return Parameter <NR2> Point 0.0001~60000 Returns the point duration time. MAX/MIN Returns the allowable maximum and
PEL-2000 Programming Manual 154 Parameter OFF/0 Off ON/1 On Example :SEQ:END:LOAD 0 On End Load = Off. Query Syntax :SEQuence:END:LOAD? Return Pa
COMMAND DETAILS 155 Query Example :SEQ:VOLT:RANG? 500 Returns the voltage range. In this case high for the PEL-2041. :SEQuence:LOOP:STARt Channel
PEL-2000 Programming Manual 156 Query Syntax :SEQuence:CHANnel:TIME? Return Parameter <NR1> Point 1~max channels Returns the channel durat
COMMAND DETAILS 157 Example :SEQ:TRIG:IN 0 Trigger IN is on. Query Syntax :SEQuence:TRIGger:IN? Return Parameter <NR1> Trigger IN 0 Off 1
PEL-2000 Programming Manual 158 Syntax :SEQuence:TRIGger:IN:CHANnel <NR1> Parameter <NR1> Channel <NR1> Channel 1 CH1 32 CH 6
COMMAND DETAILS 159 GLOBal Subsystem :GLOBal:CONFigure:VOLTage:RANGe ... 159 :GLOBal:LOAD:SHORt ...
PEL-2000 Programming Manual 16 List of Commands in Functional Order Common Commands *CLS ...
PEL-2000 Programming Manual 160 Syntax :GLOBal:MODE {CCL|CCH|CCDL|CCDH|CRL|CRH|CRDL|CRDH|CV|CPL|CPH} Parameter CCL CC static mode, low range CCH
COMMAND DETAILS 161 Command Error Codes Description The PEL has a number of specific error codes. Use the SYSTem:ERRor command to recall the erro
PEL-2000 Programming Manual 162 STATUS REGISTERS To program the PEL-200 Series effectively, the Status Register structure needs to be understood.
STATUS REGISTERS 163 BIT WEIGHT1 2 4 8OR16CONDITION1 2 4 8PTR/NTR1 2 4 8EVENT1 2 4 8ENABLEOC OV OP RV OTProtection0 1 2 3 4Bit positionBIT WEIGHT1
PEL-2000 Programming Manual 164 Channel Status Description Each channel has a dedicated Channel Status Register group. These registers show if an
STATUS REGISTERS 165 G/N The Go/NoGo bit is set when Go/NoGo limits have been exceeded, when Go/NoGo SPEC has been enabled. UVP If the under vol
PEL-2000 Programming Manual 166 Channel Summary Registers834221101287646325164Bit weightBit PositionEVENTENABLECH4 CH3 CH2 CH1CH8 CH7 CH6 CH5CH4
STATUS REGISTERS 167 UVP Under Voltage Protection Condition Register The Questionable Status Condition Register indicates the status of the electr
PEL-2000 Programming Manual 168 Standard Event Status Description The Standard Event Status Registers indicate any programming errors that occur.
STATUS REGISTERS 169 CME The Command Error bit is set when a syntax error has occurred. The CME bit can also be set when a <GET> command is
COMMAND OVERVIEW 17 Configure :CONFigure:VOLTage:ON ... 38 :CONFigure:VOLTage:RANGe ...
PEL-2000 Programming Manual 170 MSS & RQS The Master Summary Status is used with the *STB? query. When the *STB? query is read the MSS bit is
PEL-2000 Programming Manual 18 Current :CURRent:STATic:RECall ... 56 :CURRent:STATic:L1/L2 ...
COMMAND OVERVIEW 19 Measure :MEASure:VOLTage? ... 80 :MEASure:CURRent? ...
September 2012 edition This manual contains proprietary information which is protected by copyright. All rights are reserved. No part of this manual
PEL-2000 Programming Manual 20 Program :PROGram:FILE ... 94 :PROGram:SEQuence ...
COMMAND OVERVIEW 21 Specification :SPECification:UNIT ... 118 :SPECification[:PASS]? ...
PEL-2000 Programming Manual 22 System :SYSTem:ERRor? ... 141 :SYSTem:VERSion? ...
COMMAND OVERVIEW 23 Global :GLOBal:CONFigure:VOLTage:RANGe ... 159 :GLOBal:LOAD:SHORt ...
PEL-2000 Programming Manual 24 COMMAND DETAILS The Command details chapter shows the detailed syntax, equivalent panel operation, and example for
COMMAND DETAILS 25
PEL-2000 Programming Manual 26 Common commands *CLS ... 26 *ESE ...
COMMAND DETAILS 27 *ESE Status Command Description The Standard Event Status Enable command determines which events in the Standard Event Status
PEL-2000 Programming Manual 28 Return Parameter <NR1> Bit(s) Set <NR1> Bit(s) Set 4 QYE 32 CME 8 DDE 64 ~ 16 EXE 128 ~ Example *ESR
COMMAND DETAILS 29 Query Example *OPC? 1 All pending operations are completed. *RCL Status Command Description The Recall Instrument State comm
TABLE OF CONTENTS 3 Table of Contents INTERFACE OVERVIEW ... 5 Rear Panel Overview ...
PEL-2000 Programming Manual 30 *SAV All Channels Description Saves the data memory into the specified save slot. Syntax *SAV <NR1> Parame
COMMAND DETAILS 31 Example *SRE? 48 Returns settings of the Service Request Enable Register. Here ESB and MAV are returned. *STB? Status Command
PEL-2000 Programming Manual 32 Abort Subsystem :ABORt ... 32 :ABORt Al
COMMAND DETAILS 33 Channel Subsystem :CHANnel[:LOAD] ... 33 :CHANnel:ACTive ...
PEL-2000 Programming Manual 34 :CHANnel:ACTive Channel Specific Command Description This command is for compatibility with other instruments on
COMMAND DETAILS 35 :CHANnel:SYNCon:ALL All Channels Description Turns independent mode on or off for all the channels. Syntax :CHANnel:SYNCon:ALL
PEL-2000 Programming Manual 36 MAX Last channel MIN First channel Example :CHAN:DISP 1 Sets to the active channel on the display to ch1. Query S
COMMAND DETAILS 37 :MEMo? Channel Specific Query Description Creates or returns the “memo” that is displayed in the “System Information” screen i
PEL-2000 Programming Manual 38 CONFIGURE Subsystem :CONFigure:VOLTage:ON ... 38 :CONFigure:VOLTage:RANG
COMMAND DETAILS 39 Example :CONF:VOLT:ON 30MV Set Von to 30 millivolts. Query Syntax :CONFigure:VOLTage:ON? Return Parameter <NR2> I unit =
PEL-2000 Programming Manual Power Subsystem ... 135 SYSTEM Subsystem ... 141 Memory Su
PEL-2000 Programming Manual 40 :CONFigure:VOLTage:LATch Channel Specific Command Description Turn Von Latch on or off for the specific channel.
COMMAND DETAILS 41 Query Example :CONF:AUTO:LOAD? 1 Auto load is On. :CONFigure:AUTO:MODE All channels Description Configures the Auto Load mode
PEL-2000 Programming Manual 42 Return Parameter <NR1> SOUND Status 0 Off 1 On Query Example :CONF:SOUND? 0 Sound is off for the specific c
COMMAND DETAILS 43 Parameter OLD/0 Old UPDATED/1 Updated Example :CONF:LOAD OLD Configuration type set as OLD. Query Syntax :CONFigure:LOAD? Retu
PEL-2000 Programming Manual 44 :CONFigure:PROTection:CURRent:LEVel Channel Specific Command Description Sets the current protection level for the
COMMAND DETAILS 45 :CONFigure:PROTection:VOLTage:STATe Channel Specific Command Description Sets the voltage protection for the current/specific
PEL-2000 Programming Manual 46 MIN Sets to the minimum level MAX Sets the voltage limit to the maximum level Example :CONF:PROT:VOLT:LEV MAX Sets
COMMAND DETAILS 47 :CONFigure:PROTection:POWer:LEVel Channel Specific Command Description Sets the power protection level for the current/specifi
PEL-2000 Programming Manual 48 :CONFigure:PROTection:UVP:LEVel Channel Specific Command Description Sets the under voltage protection level for t
COMMAND DETAILS 49 Example :CONF:RESP 0 Response set to normal. Query Syntax : CONFigure:RESPonse? Return Parameter <NR1> Response 0 Norma
INTERFACE OVERVIEW 5 INTERFACE OVERVIEW This manual describes how to use the PEL-2000’s remote command functionality and lists the command details
PEL-2000 Programming Manual 50 Query Example : CONF:GRO:UNIT? 2 2 units are set for the parallel mode. :CONFigure:GROup:MODE Channel Specific Comm
COMMAND DETAILS 51 Utility Subsystem :UTILity:AUTO:LOAD ... 51 :UTILity:AUTO:MODE ...
PEL-2000 Programming Manual 52 :UTILity:AUTO:MODE System Command Description Sets the mainframe auto mode as load or program. Upon startup the ma
COMMAND DETAILS 53 1 On Query Example :UTIL:SOUN? 0 Sound is currently set to off. :UTILity:REMote System Command Description Turns the remote c
PEL-2000 Programming Manual 54 :UTILity:TIME System Command Description Sets the date and time on the mainframe. Syntax :UTILity:TIME [aard] Par
COMMAND DETAILS 55 0 Old 1 Updated Query Example :UTIL:LOAD? 1 The knob style is set to Updated. :UTILity:IDENtify System Command Description F
PEL-2000 Programming Manual 56 Current Subsystem :CURRent:STATic:RECall ... 56 :CURRent:STATic:L1/L2
COMMAND DETAILS 57 Query Example :CURR:STAT:REC? 0 A Value is active. :CURRent:STATic:L1/L2 Channel Specific Command Description Sets the A/B Val
PEL-2000 Programming Manual 58 Query Example :CURR:STAT:L2? 2 Returns the current setting (2 A) for B Value. :CURRent:STATic:RISE/FALL Channel Sp
COMMAND DETAILS 59 :CURRent:STATic:LOW:AVALue/BVALue Channel Specific Command Description Sets the low range A/B Value for constant current stati
PEL-2000 Programming Manual 6 Configuring the USB Interface USB connection PC side connector Type A, host PEL-2000 side connector Type B, device
PEL-2000 Programming Manual 60 :CURRent:STATic:LOW:RISE/FALL Channel Specific Command Description Sets the low range rising/falling slew rates.
COMMAND DETAILS 61 AVALue 10 Sets A Value to 10 Amps. (high range only) BVALue 20 Sets B Value to 20 Amps. (high Range only) AVALue MIN Sets A
PEL-2000 Programming Manual 62 RISE/FALL MIN Sets to the slowest rising/falling slew rate. RISE/FALL MAX Sets to the fastest rising/falling slew
COMMAND DETAILS 63 L1/L2 MAX Sets L1 or L2 to the maximum Level for the specific channel. Example :CURR:DYN:L1 10 In CC dynamic mode, Set L1 (lev
PEL-2000 Programming Manual 64 Return Parameter <NR2> [MAX|MIN] Slew rate 1 Unit=1 amp/uS Returns the slew rate. MAX/MIN Returns the allow
COMMAND DETAILS 65 Query Example :CURR:DYN:LOW:T1? 2.5 :CURR:DYN:LOW:T1? MIN 0.000025 Returns the T1 time of 2.5 seconds. Returns the minimum T1 t
PEL-2000 Programming Manual 66 MAX/MIN Returns the allowable maximum and minimum. Query Example :CURR:DYN:LOW:L2? 2.0400 Returns current for the
COMMAND DETAILS 67 :CURRent:DYNamic:LOW:T1/T2 Channel Specific Command Description Sets the low range timers T1 or T2 for CC dynamic mode for the
PEL-2000 Programming Manual 68 Syntax :CURRent:DYNamic:HIGH:L1/L2 <NRf+>[A] Parameter NRf+[A] L1 10 Sets L1 to 10 Amps. (High range only)
COMMAND DETAILS 69 RISE/FALL 1 Sets the rising/falling slew rate to 1A/uS RISE/FALL MIN Sets to the slowest rising/falling slew rate. RISE/FALL
INTERFACE OVERVIEW 7 7. On the PC, activate a terminal application such as MTTTY (Multi-Threaded TTY). To check the COM port No., see the Device
PEL-2000 Programming Manual 70 Example :CURR:DYNA:HIGH:T1 10S Sets the high range T1 time to 10 seconds for the specific channel. Query Syntax :CU
COMMAND DETAILS 71 FETCH Subsystem :FETCh:VOLTage? ... 71 :FETCh:CURRent? ...
PEL-2000 Programming Manual 72 :FETCh:POWer? Channel Specific Status Command Description This query returns the real-time power of the load modul
COMMAND DETAILS 73 Parameter <aard> CH1,CH2,CH3,CH4,CH5,CH6,CH7,CH8 Returns all the voltage values from all the channels, 1-8(PEL-2004)/1-
PEL-2000 Programming Manual 74 Parameter <aard> CH1,CH2,CH3,CH4,CH5,CH6,CH7,CH8 Returns all the power values from all the channels, 1-8(PE
COMMAND DETAILS 75 LOAD Subsystem :LOAD[:STATe] ... 75 :LOAD:SHORt[:STATe] ...
PEL-2000 Programming Manual 76 Parameter ON/1 Shorting is On OFF/0 Shorting is Off Example :LOAD:SHOR ON Short circuits the load module channel.
COMMAND DETAILS 77 Description Returns the protection levels for electronic load Query Syntax :LOAD:PROTection? Query Example :LOAD:PROT? Clears t
PEL-2000 Programming Manual 78 Query Example :LOAD:TIME? 5.1 Returns the load on time as 5.1 seconds. :LOAD:DELay Channel Specific Command Desc
COMMAND DETAILS 79 Query Example :LOAD:TYPE? 0 The normal load type is active
PEL-2000 Programming Manual 8 RS-232C Interface Configuration RS-232C configuration Connector DB-9, Male Baud rate 2400, 4800, 9600, 19200, 38400
PEL-2000 Programming Manual 80 Measure Subsystem :MEASure:VOLTage? ... 80 :MEASure:CURRent? ..
COMMAND DETAILS 81 :MEASure:POWer? Channel Specific Command Description This query returns the measured power of the specific channel. Query Sy
PEL-2000 Programming Manual 82 :MEASure:SCAN Channel Specific Command Description This command allows the mainframe to scan all the load modules.
COMMAND DETAILS 83 Query Example :MEAS:ALLV? 2.5000, 3.0000, 0.0000, 0.0000, 0.0000, 0.0000, 5.500, 0.0000 Channel 1 and 2 have voltages of 2.5 an
PEL-2000 Programming Manual 84 Query Example :MEAS:ALLP? 0.0000, 0.0000, 0.0000 ,0.0000, 0.0000, 0.0000, 1.5000, 3.2000 Channels 1 to 6 have no po
COMMAND DETAILS 85 MODE Subsystem :MODE ... 85 :MODE Channel Specific
PEL-2000 Programming Manual 86 CCDL CC dynamic mode, low range CCDH CC dynamic mode, high range CRL CR static mode, low range CRH CR static mo
COMMAND DETAILS 87 OCP Test Automation Commands :OCP:EDIT:CHANnel? ... 87 :OCP:CHANnel:RANGe ...
PEL-2000 Programming Manual 88 :OCP:CHANnel:RANGe Channel Specific Command Description Sets or queries the channel range. High(CC Mode High) or L
COMMAND DETAILS 89 :OCP:CHANnel:END Channel Specific Command Description Sets the ending current value for the test. The value must be higher tha
INTERFACE OVERVIEW 9 5. Edit the Baud rate, Stop bit and parity. Baud rate 2400, 4800, 9600, 19200, 38400 Stop Bit Range 1,2 Parity Range
PEL-2000 Programming Manual 90 :OCP:CHANnel:LAST Channel Specific Command Description Queries or sets the current value for after the DUT OCP pr
COMMAND DETAILS 91 :OCP:CHANnel:DELay Channel Specific Command Description Queries or sets the test delay time for the OCP Test Automation functi
PEL-2000 Programming Manual 92 :OCP:CHANnel:ACTive Channel Specific Command Description Queries or sets which bit(s) are the active channel for t
COMMAND DETAILS 93 1 OCP test active Query Example :OCP:STAT? 0 The test has ended. :OCP:SAVE Channel Spe
PEL-2000 Programming Manual 94 Program Subsystem :PROGram:FILE ... 94 :PROGram:SEQuenc
COMMAND DETAILS 95 :PROGram:SEQuence Program Number Specific Description Sets the Sequence number for the current program number. Syntax :PROGra
PEL-2000 Programming Manual 96 Query Example :PROG:MEM? 1 The memory number for the current program/sequence is 001. :PROGram:SEQuence:SHORt:CHAN
COMMAND DETAILS 97 :PROGram:SEQuence:SHORt:TIME Program Number Specific Description Sets the short time (seconds) for the current program sequenc
PEL-2000 Programming Manual 98 SKIP Skip mode: current program sequence is skipped. Example :PROG:SEQ:MODE: AUTO The current program sequence is
COMMAND DETAILS 99 Query Example :PROG:ACT? 12 Channels 3 and 4 are active. :PROGram:CHAin Program Number Specific Description Chains the curre