Query Example
:POWer:HIGH:BVAL? AX
2
Returns the maximum
power allowed for the
channel/range.
:POWer:HIGH:CURRent
Channel Specific
Command
Description
Sets the current limit for constant power mode for
the high range only.
Syntax
:POWer:HIGH:CURRent <NRf+>[A]
Parameter
<NRf+>[A]
1
Sets the current limit to
1A.
1A
Sets the current limit to
1A.
MIN
Sets the current limit to
the minimum level for the
specific channel.
MAX
Sets the current limit to
the maximum level for the
specific channel.
Example
:POW:HIGH:CURR 1
Sets the current limit to
1A.
Query Syntax
:POW:HIGH:CURRent? [MAX|MIN]
Return Parameter
<NR2> [MAX|MIN]
Current
1 unit = 1 amp
Returns the current limit.
MAX/MIN
Returns the allowable
maximum and minimum.
Query Example
:POW:HIGH:CURR?
7.0
Returns the current limit
for the specific channel.