PEL-2000 Programming Manual
132
MAX
Sets the voltage to the
maximum value for the
channel
Example
:VOLT:AVAL 10V
Sets A Value to 10 volts
for the specific channel
:VOLT:BVAL MAX
Sets B Value to the
maximum allowed
voltage for the specific
channel. (single channel
only)
Query Syntax
:VOLTage:AVALue/BVALue? [MAX|MIN]
Return Parameter
<NR2> 1 unit = 1 volt
Voltage
10
Returns the voltage of the
specific channel.
MAX/MIN
Returns the allowable
maximum and minimum.
Query Example
:VOLT:AVAL?
5
:VOLT:AVAL? MAX
81.6000
A Value is set to 5 volts.
Returns the maximum
settable voltage.
:VOLTage:CURRent
Channel Specific
Command
Description
Sets the current limit in CV mode.
Syntax
:VOLTage:CURRent <NRf+>[ A ]
Parameter
<NRf+>[ A ]
Current limit
1
1 Amp
1A
1 Amp
MIN
Sets the current limit to
the minimum value for the
channel