COMMNAND OVERVIEW
147
Syntax
:STATus:OPERation:PTRansition <NR1>
Query Syntax
:STATus:OPERation:PTRansition?
Parameter/
Return Parameter
<NR1>
Condition
<NR1>
Condition
1
CAL
All other
bits
Not used
32
WTG
Example
:STATus:OPERation:PTRansition 32
Configures the WTG bit (Bit 5) in the Operation Status
Condition register to set the corresponding bit in the
Operation Status Enable register on a positive
transition.
Query example
:STATus:OPERation:PTRansition?
>32
The WTG bit is configured to PTR in the Operation
Status PTR filter.
:STATus:CSUMmary:CONDition?
Set
Query
Description
Returns the status of the CSummary Status
Condition register. See page 153 for details.
Query Syntax
:STATus:CSUMmary:CONDition?
Return parameter
<NR1>
Condition
<NR1>
Condition
1
CC
256
PRUN
2
CR
All other
bits
Not used
4
CV
8
CP
Query example
:STATus:CSUMmary:CONDition?
>1
Indicates the unit is in CC mode.
:STATus:CSUMmary:ENABle
Set
Query
Description
Sets which events are enabled in the CSummary
Status Enable register. The mask values are the bit
weights of the events. See page 153 for details.