Gw-instek PEL-3000 Series Programming Manual Bedienungsanleitung Seite 98

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 174
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 97
PEL-3000 Programming Manual
96
Example
:POWer:T2 0.200
Sets the T2 timer time to 200ms.
Query example
:POWer:T2?
>0.200
Returns the T2 timer time as 200ms.
:POWer:FREQuency
Set
Query
Description
Sets the CP dynamic mode switching frequency.
This command along with the “:POWer:Duty”
command is used when the dynamic time setting
is set to “Freq./Duty”.
This command is only applicable for dynamic
mode.
Syntax
:POWer:FREQuency {<NRf> | MINimum | MAXimum}
Query Syntax
:POWer:FREQuency?
Related
Commands
:POWer:DUTY
Parameter
<NRf>
Sets the switching
frequency in hertz.
MINIMUM or MIN
Minimum frequency
MAXIMUM or MAX
Maximum frequency
Return parameter
<NR2>
Returns the frequency in
hertz.
Example
:POWer:FREQuency 60
Sets the frequency to 60Hz.
Query example
:POWer:FREQuency?
>60
Returns the switching frequency (60Hz).
Seitenansicht 97
1 2 ... 93 94 95 96 97 98 99 100 101 102 103 ... 173 174

Kommentare zu diesen Handbüchern

Keine Kommentare