COMMNAND OVERVIEW
97
:POWer:DUTY
Set
Query
Description
Sets the duty cycle for the CP dynamic mode
switching frequency. This command along with
the “:POWer:FREQuency” command is used when
the dynamic time setting is set to “Freq./Duty”.
This command is only applicable for dynamic
mode.
Syntax
:POWer:DUTY {<NRf> | MINimum | MAXimum}
Query Syntax
:POWer:DUTY?
Related
Commands
:POWer:FREQuency
Parameter
<NRf>
Sets the duty as a
percentage.
MINIMUM or MIN
Minimum duty
MAXIMUM or MAX
Maximum duty
Return parameter
<NR2>
Returns the duty as a
percentage.
Example
:POWer:DUTY 50
Sets the duty to 50%.
Query example
:POWer:DUTY?
>50
Returns the duty (50%).