Seitenansicht 124
REMOTE CONTROL
123
Parameter
<ampl>
<NRf> power or voltage
Return parameter
<NR3>
Example
:ACPR: HLIM -3.0e+1
[:SENSe]:ACPR:LLIMit
Set
Query
Description
Sets or queries the low limit for the main channel.
Used with ACPR measurement.
Syntax
[:SENSe]:ACPR:LLIMit <ampl>
Query Syntax
[:SENSe]:ACPR:LLIMit?
Parameter
<ampl>
<NRf> power or voltage
Return parameter
<NR3>
Example
:ACPR:ACH1:LLIM -5.0e+1
[:SENSe]:ACPR:HELP:STATe
Set
Description
Turns the on-screen help on/off.
Syntax
[:SENSe]:ACPR:HELP:STATe {OFF|ON|0|1}
Parameter
0
Turn help off.
1
Turn help on.
OFF
Turn help off.
ON
Turn help on.
Example
:ACPR:HELP:STAT ON
[:SENSe]:ACPR:SPACe
Set
Query
Description
Sets or queries the channel spacing between the
main channels.
Syntax
[:SENSe]:ACPR:SPACe <freq>
Query Syntax
[:SENSe]:ACPR:SPACe?