REMOTE CONTROL
93
Description
Turns the SEM measurement on/off or queries its
state.
Syntax
:CALCulate:SEM:STATe {ON|OFF|1|0}
Query Syntax
:CALCulate:SEM:STATe?
Parameter
0
Turns SEM off.
1
Turns SEM on.
OFF
Turns SEM off.
ON
Turns SEM on.
Return parameter
0
SEM is off.
1
SEM is on.
Example
:CALC:SEM:STAT ON
:CALCulate:SEM:OFFSet<n>:RESult?
Query
Description
Returns the start, stop frequencies as well as the
pass/fail limits and judgements for the chosen
offset.
Query syntax
:CALCulate:SEM:OFFSet<n>:RESult?
Parameter
<n>
Offset number 1~5.
Return parameter
<start freq>
Start frequency of the selected channel
<low dBm>
Lower dBm measurement
<low p/f>
Lower pass/fail limit judgment.
0 = pass, 1 = fail.
<stop freq>
Stop frequency of the selected channel
<upp dBm>
Upper dBm measurement
<upp p/f>
Upper pass/fail limit judgment
0 = pass, 1 = fail.
Example
:CALC:SEM:OFFS1:RES?
>9e+7, -7.9e+1,0,1.7e+7,-6.9e+1,0
:CALCulate:TOI:DIFFerential?
Query
Description
Returns the third order intermodulation distortion.
Query syntax
:CALCulate:TOI:DIFFerential?