GSP-930 Programming Manual
76
:CALCulate:JITTer:PHASe?
Query
Returns the carrier phase jitter in radians.
:CALCulate:JITTer:PHASe?
<NR3>
Rad
:CALC:JITT:PHAS?
>1.5307e+01
:CALCulate:JITTer:TIME?
Query
Returns the carrier jitter time in seconds.
:CALCulate:JITTer:TIME?
<NR3>
Seconds
:CALC:JITT:TIME?
>.5.31e-08
:CALCulate:LIMit<n>:CLEar
Set
Clears the High Limit, Low Limit and the
Pass/Fail state for the selected limit line.
:CALCulate:LIMit<n>:CLEar
<n>
Selected limit line
:CALC:LIM1:CLE
:CALCulate:LIMit<n>:DATA
Set
Query
Sets or queries the frequency, amplitude limit of
every point in the selected limit line. The data is
stored in CSV format.
There are total of 10 pairs of data points (20 data
entries in total) for the <csv data> data.
:CALCulate:LIMit<n>:DATA <csv data>