REMOTE CONTROL
149
[:SENSe]:SEMask:OFFSet<n>:ADDition:
STARt:ABSolute?
Query
Description
Returns the “start” amplitude (dBm) of the
Absolute Mask for the selected offset for the
additional requirements of the selected 3GPP SEM
test.
Query syntax
[:SENSe]:SEMask:OFFSet<n>:ADDition:STARt:
ABSolute?
Parameter/
Return parameter
<n>
Offset 1 to 5
<NR3>
Amplitude at start frequency
Example
:SEM:OFFS1:ADD:STAR:ABS?
>-1.5e+1
[:SENSe]:SEMask:OFFSet<n>:ADDition:
STOP:ABSolute?
Query
Description
Returns the “Stop” amplitude (dBm) of the
Absolute Mask for the selected offset for the
additional requirements of the selected 3GPP SEM
test.
Query syntax
[:SENSe]:SEMask:OFFSet<n>:ADDition:STOP:
ABSolute?
Parameter/
Return parameter
<n>
Offset 1 to 5
<NR3>
Amplitude at stop frequency
Example
:SEM:OFFS1:ADD:STOP:ABS?
>-1.5e+1
[:SENSe]:SEMask:OFFSet<n>:BANDwidth|
BWIDth[:RESolution]
Set
Query
Description
Sets or queries the resolution bandwidth of the
selected offset.