GSP-930 Programming Manual
134
Turn the detection mode to manual (off).
Turn the detection mode to auto (on).
Turn the detection mode to manual (off).
Turn the detection mode to auto (on).
The detection mode is set to manual.
The detection mode is set to automatic.
Turns the EMI filter on/off or queries its state.
[:SENSe]:EMIFilter:STATe {OFF|ON|0|1}
[:SENSe]:EMIFilter:STATe?
[:SENSe]:EMIFilter:BANDwidth|BWIDth
[:RESolution]
Sets the EMI filter bandwidth (must be set to the
exact bandwidth).
[:SENSe]:EMIFilter:BANDwidth|BWIDth[:RESolution]
<freq>
<NRf>
(Only 200Hz, 9kHz, 120kHz are valid
settings)