REMOTE CONTROL
69
:CALCulate:CTB:RESult?
Query
Description
Returns the CTB measurement result in dB.
Query Syntax
:CALCulate:CTB:RESult?
Return parameter
<NR3>
CTB measurement in dB
Query Example
:CALC:CTB:RES?
>-4.237e+01
:CALCulate:CTB:STATe
Set
Query
Description
Sets or queries the state of the CTB measurement
function.
Syntax
:CALCulate:CTB:STATe {ON|OFF|1|0}
Query Syntax
:CALCulate:CTB:STATe?
Parameter
0
CTB is off.
1
CTB is on.
OFF
CTB is off.
ON
CTB is on.
Return parameter
0
CTB is off.
1
CTB is on.
Query Example
:CALC:CTB:STAT?
>0
:CALCulate:CTB:RESTart
Set
Description
Restarts the CTB measurement.
Syntax
:CALCulate:CTB:RESTart
:CALCulate:DELTamarker<n>:PAIR:SPAN
Set
Description
Sets the span between the chosen marker and the
delta marker.
Seitenansicht 70